Frauenthal Theater Technical Information
CAPACITY - 1748

 

LOADING DOCK
Loading doors open to alley between 3rd and 4th Streets.
Trucks may load at right angles to doors.
No parking in the alley.
Door width 5'7"
Door height 8'
There is a 2' ramp down to stage level.
No Forklift.
Also there is a 8’ x 8’ loading door with a ramp down from alley and a single truck dock.

STAGE
Proscenium opening: 41'6w, 30'h
Stage depth: Plaster line to upstage wall 29’6” (Usable 29’)
Stage extension/pit cover lip to back wall 41’3”
Stage apron: From apron edge to plaster line 3’10”
From apron of stage to front edge of orch. Pit 7’10”
From plaster line to front edge of orch. Pit 11’8”
Wing space: Stage Right 10'w x 29'd
Stage Left 17'w x 29'd

Wing-to-Wing Crossover located behind upstage wall.

Grid Height: 60ft Pipe, high trim 55’, low trim 4’ off deck

STAGE FLOOR
Center Stage: Yellow Pine over air (21 traps)
All other areas: Resilient Yellow Pine
Stage floor currently covered with black Masonite skin

PROPS & DROPS
Barton c. 1929 Pipe Organ in excellent condition
Red grand lambrequin curtain, fixed in proscenium arch
Red grand curtain (travel, fly, permanent) 32'h x 54'w
Black house traveler (travel, fly, permanent) 28'h x 54'w
Black legs: 4 sets, 28'h x 15'w each leg
Black borders: 4 - 8'h x 50'w
Black drops - 3 - 28'h x 54'w, w/ split overlap at centers
Movie Screen: 22'h x 42'w, permanent
Black Seamless Scrim (sharkstooth) with pocket 28'h x 40'w
Natural Muslin Cyc Drop (seamless) 25'h x 60'w
Brown Orchestra Scrim 50'h x 28'w

ELECTRICAL SERVICE
(Anyone using this system must be approved by Frauenthal management)
Power: 1 - Three-phase 120/208, 400 amps per leg
1 - Three-phase 120/208, 200 amps per leg
1 - single-phase, 200 amps per leg
Located Stage Left: cold water pipe ground & mechanical ground.

LIGHTING CONTROL
(Anyone using this system must be approved by Frauenthal management)
Booth located house right rows Q-S
Electronic Theater Controls Expression III lighting desk with 212 - 2.4kw dimmers available for stage lighting. House lights are on the same system.
A stage manager address panel is also located off left & may be used in booth location

LIGHTING INSTRUMENTATION
Connectors: 2 P & G, Three Pin Stage Plugs.
Follow spots: 2 Lycian Super Arc 1267 Long Throw (Frauenthal Theater only)
2 Lycian Super Arc 1266 Medium Throw

STAGE LIGHTING INCLUDES (based on availability)
12 - ETC Source Four 410-b Ellipsoidal
66 - ETC Source Four 419-B Ellipsoidal
64 - ETC Source Four 426-B Ellipsoidal
48 - ETC Source Four 436-B Ellipsoidal
36 - ETC Source Four PAR-B w/ variable lenses
36 - Altman PAR64 w/ varying focus lamps
10 - 6'4" Zipstrips, 3 circuit
6 - 3 Cell Cyc Lights

SOUND
(Anyone using this system must be approved by Frauenthal management)
Booth located house right rows O-Q
DDA S8 48Channel Board
Center point cluster with a mixture of EAW and Community horns and speakers
W/ right and left EAW boxes that hang from chain hoist
Under balcony delayed system
4 Monitor Channel's - 1 with 1/3 octave EQ,
Infrared hearing impaired system

DRESSING ROOMS
4 Capacity of 8 each
Located Stage Right on 4 levels with lavatory, toilet & shower
1 Capacity of 2 with lavatory, toilet & shower (Fully handicapped accessible)
1 Capacity of 2; with lavatory, toilet & shower
Located Upstage Left crossover

COMMUNICATION
Clear-Com System: 12 sets based on availability
Stations located Stage Left and Stage Right, balcony follow spot positions & booths.
 


Compass Facility Management, Inc.